↓ Skip to main content

PLOS

Performance of Multiplex Cytokine Assays in Serum and Saliva among Community-Dwelling Postmenopausal Women

Overview of attention for article published in PLOS ONE, April 2013
Altmetric Badge

Mentioned by

facebook
1 Facebook page

Citations

dimensions_citation
59 Dimensions

Readers on

mendeley
90 Mendeley
Title
Performance of Multiplex Cytokine Assays in Serum and Saliva among Community-Dwelling Postmenopausal Women
Published in
PLOS ONE, April 2013
DOI 10.1371/journal.pone.0059498
Pubmed ID
Authors

Richard W. Browne, Alpdogan Kantarci, Michael J. LaMonte, Christopher A. Andrews, Kathleen M. Hovey, Karen L. Falkner, Ali Cekici, Danielle Stephens, Robert J. Genco, Frank A. Scannapieco, Thomas E. Van Dyke, Jean Wactawski-Wende

Abstract

Multiplexing arrays increase the throughput and decrease sample requirements for studies employing multiple biomarkers. The goal of this project was to examine the performance of Multiplex arrays for measuring multiple protein biomarkers in saliva and serum. Specimens from the OsteoPerio ancillary study of the Women's Health Initiative Observational Study were used. Participants required the presence of at least 6 teeth and were excluded based on active cancer and certain bone issues but were not selected on any specific condition. Quality control (QC) samples were created from pooled serum and saliva. Twenty protein markers were measured on five multiplexing array panels. Sample pretreatment conditions were optimized for each panel. Recovery, lower limit of quantification (LLOQ) and imprecision were determined for each analyte. Statistical adjustment at the plate level was used to reduce imprecision estimates and increase the number of usable observations. Sample pre-treatment improved recovery estimates for many analytes. The LLOQ for each analyte agreed with manufacturer specifications except for MMP-1 and MMP-2 which were significantly higher than reported. Following batch adjustment, 17 of 20 biomarkers in serum and 9 of 20 biomarkers in saliva demonstrated acceptable precision, defined as <20% coefficient of variation (<25% at LLOQ). The percentage of cohort samples having levels within the reportable range for each analyte varied from 10% to 100%. The ratio of levels in saliva to serum varied from 1∶100 to 28∶1. Correlations between saliva and serum were of moderate positive magnitude and significant for CRP, MMP-2, insulin, adiponectin, GM-CSF and IL-5. Multiplex arrays exhibit high levels of analytical imprecision, particularly at the batch level. Careful sample pre-treatment can enhance recovery and reduce imprecision. Following statistical adjustments to reduce batch effects, we identified biomarkers that are of acceptable quality in serum and to a lesser degree in saliva using Multiplex arrays.

Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 90 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Spain 1 1%
United States 1 1%
Unknown 88 98%

Demographic breakdown

Readers by professional status Count As %
Researcher 19 21%
Student > Ph. D. Student 17 19%
Student > Master 17 19%
Student > Bachelor 9 10%
Student > Doctoral Student 5 6%
Other 10 11%
Unknown 13 14%
Readers by discipline Count As %
Medicine and Dentistry 21 23%
Agricultural and Biological Sciences 17 19%
Biochemistry, Genetics and Molecular Biology 7 8%
Psychology 7 8%
Engineering 5 6%
Other 16 18%
Unknown 17 19%