ā†“ Skip to main content

PLOS

Feasibility of an Ingestible Sensor-Based System for Monitoring Adherence to Tuberculosis Therapy

Overview of attention for article published in PLOS ONE, January 2013
Altmetric Badge

Mentioned by

news
1 news outlet
blogs
2 blogs
policy
2 policy sources
twitter
8 X users
patent
3 patents

Citations

dimensions_citation
131 Dimensions

Readers on

mendeley
236 Mendeley
Title
Feasibility of an Ingestible Sensor-Based System for Monitoring Adherence to Tuberculosis Therapy
Published in
PLOS ONE, January 2013
DOI 10.1371/journal.pone.0053373
Pubmed ID
Authors

Robert Belknap, Steve Weis, Andrew Brookens, Kit Yee Au-Yeung, Greg Moon, Lorenzo DiCarlo, Randall Reves

Abstract

Poor adherence to tuberculosis (TB) treatment hinders the individual's recovery and threatens public health. Currently, directly observed therapy (DOT) is the standard of care; however, high sustaining costs limit its availability, creating a need for more practical adherence confirmation methods. Techniques such as video monitoring and devices to time-register the opening of pill bottles are unable to confirm actual medication ingestions. A novel approach developed by Proteus Digital Health, Inc. consists of an ingestible sensor and an on-body wearable sensor; together, they electronically confirm unique ingestions and record the date/time of the ingestion. A feasibility study using an early prototype was conducted in active TB patients to determine the system's accuracy and safety in confirming co-ingestion of TB medications with sensors. Thirty patients completed 10 DOT visits and 1,080 co-ingestion events; the system showed 95.0% (95% CI 93.5-96.2%) positive detection accuracy, defined as the number of detected sensors divided by the number of transmission capable sensors administered. The specificity was 99.7% [95% CI 99.2-99.9%] based on three false signals recorded by receivers. The system's identification accuracy, defined as the number of correctly identified ingestible sensors divided by the number of sensors detected, was 100%. Of 11 adverse events, four were deemed related or possibly related to the device; three mild skin rashes and one complaint of nausea. The system's positive detection accuracy was not affected by the subjects' Body Mass Index (pā€Š=ā€Š0.7309). Study results suggest the system is capable of correctly identifying ingestible sensors with high accuracy, poses a low risk to users, and may have high patient acceptance. The system has the potential to confirm medication specific treatment compliance on a dose-by-dose basis. When coupled with mobile technology, the system could allow wirelessly observed therapy (WOT) for monitoring TB treatment as a replacement for DOT.

X Demographics

X Demographics

The data shown below were collected from the profiles of 8 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 236 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Switzerland 1 <1%
France 1 <1%
Ireland 1 <1%
United Kingdom 1 <1%
Japan 1 <1%
United States 1 <1%
Unknown 230 97%

Demographic breakdown

Readers by professional status Count As %
Researcher 43 18%
Student > Master 43 18%
Student > Ph. D. Student 22 9%
Student > Bachelor 21 9%
Student > Postgraduate 14 6%
Other 43 18%
Unknown 50 21%
Readers by discipline Count As %
Medicine and Dentistry 67 28%
Nursing and Health Professions 23 10%
Engineering 16 7%
Computer Science 15 6%
Social Sciences 11 5%
Other 42 18%
Unknown 62 26%